Tissue Repair Technology
Surgeons rely on our tissue repair technology as part of their approach to addressing surgical challenges. Our portfolio is designed to support a wide range of procedural needs. Together, these solutions reflect our commitment to advancing surgical care.

Featured Tissue Repair Products
Visit our U.S. Catalog for all available products, parts and accessories.
Peri-Strips Dry Staple Line Reinforcement with Veritas Collagen Matrix Indications and Important Risk Information
Peri-Strips Dry with Veritas Collagen Matrix (PSDV) Indications
Peri-Strips Dry with Veritas Collagen Matrix (PSDV) Reinforcement is intended for use as a prosthesis for the surgical repair of soft tissue deficiencies using surgical staplers when staple line reinforcement is needed.
(Secure Grip only) PSDV-SG is intended for use as a prosthesis for the surgical repair of soft tissue deficiencies using surgical staplers when staple line reinforcement is needed. PSDV-SG can be used for reinforcement of staple lines during bariatric, gastric, small bowel, colon, and colorectal procedures.
(Circular Reinforcement only) PSDV reinforcement can be used for reinforcement of staple lines during gastric, bariatric, and small bowel procedures.
(Linear Reinforcement only) PSDV Reinforcement can be used for reinforcement of staple lines during lung and bronchus resections and during bariatric surgical procedures, and during gastric, small bowel, mesentery, colon, and colorectal procedures.
Peri-Strips Dry with Veritas Collagen Matrix (PSDV) Important Risk Information
The use of PSDV-SG is contraindicated in patients with known sensitivity to bovine or acrylic material(s).
Do not re-sterilize. Resterilization may cause changes to the tissue and negatively impact functionality of the device.
Discard all open, used, or unused components as sterility is no longer assured.
Do not use product if there is damage to the pouch or seals as sterility may be compromised.
Ensure the staple line is completely covered with the buttress, or it may result in inadequate coverage after firing.
PSDV-SG is not designed, sold, or intended for use except as indicated; doing so may result in surgical complications.
PSDV-SG configurations differ; substitution of one product for another product may reduce product performance.
Do not use PSDV-SG if the product has been submerged in liquids or if heat indicator has been activated.
Use care when removing loading unit components from the stapler to prevent buttress dislodgement.
Do not get the anvil or cartridge buttress wet before applying, or the buttress may not adhere to the stapler properly.
Ensure the anvil and cartridge side of the loading unit are on the corresponding stapler jaws or the buttress may not adhere to the stapler properly.
Final tissue compression, including PSDV-SG, must meet the range specified by the stapler manufacturer; this is especially important if staple firings are overlapped. PSDV-SG increases the total thickness of the area stapled by 0.45 mm–0.86 mm (0.018"–0.033").
Follow Instructions for Use supplied by the stapler manufacturer. Do not use PSDV-SG contrary to the stapler manufacturer’s instructions.
The cartridge and anvil sides of the PSDV-SG loading unit differ; substitution of one side for the other may interfere with alignment and adherence of the buttress strips.
The use of PSDV-SG has not been studied in lung or bronchus resection.
PSDV FULL INSTRUCTIONS FOR USE